Read Harman Kardon DVD 21 (serv.man14) EMC - CB Certificate online
page 14 of 31
Ref.No.:JSH02*1896-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2
Reliable connection of non-detachable cords:
P
not soldered to conductors of a printed circuit
board
board
P
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
P
wire secured by additional means to the conductor Cord anchorage
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by Table 8
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0.2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
P
Terminals located and shielded: test with 8 mm
strand
strand
P
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
Click on the first or last page to see other DVD 21 (serv.man14) service manuals if exist.