Read Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate online
WOORI Technology Inc. Page 20 of 83
DPR1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMI
9. Antenna Terminal Disturbance Voltage
9.1 Test Procedure
Measurements were performed in the frequency range 30 MHz to 1,000 MHz.
The level of the test signal, which was connected to the receiver through a power combiner, was set to
give 70 dBuV at the input of the receiver. The signal was an appropriate unmodulated sound carrier.
Disturbance voltage due to the local oscillator due to the local oscillator and its fundamental and
harmonic frequencies was measured with the receiver tuned to a selected number.
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial number
Due To Calibration
Test Receiver
Rohde&Schwarz
ESCS30 833364/020 2004.
09
Matching Pad
Rohde&Schwarz
RAM358.5414.02
893921.029
2005. 05
3-point Junction
Network
Hewlett Packard
11667A
18907
2005. 05
9.2 Measurement Uncertainty
Antenna terminal disturbance voltage, quasi-peak detection: ±3.0dB
9.3 Test Parameters
Port:
Antenna Terminal
Test Engineer:
J. Y. Yu
Basic Standard:
EN 55013: 2001
IF Bandwidth:
120kHz
Measurement Time:
0.2Sec
Frequency Range:
30MHz – 1GHz