WOORI Technology Inc.                                                Page 17 of 83 
                               DPR1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMI 
 
8. Radiated Disturbance 
 
8.1 Test Procedure
 
         
        The measurements were performed in the frequency range 30-1000 MHz 
        The disturbance radiation was measured on an open area test site with a reference ground plane and at a 
distance of 3 m. The height of the measuring antenna was varied between 1 to 4 m and the table was rotated 
a full revolution order to obtain maximum values of the electric field intensity.   
The measurement was made in both the vertical and horizontal polarization, and the maximum value is 
presented in the data. Disturbance radiation due to the local oscillator and its fundamental and harmonic 
frequencies was measured on a selected number of broadcast channels.   
Instrumentation used during this session: 
 
Instruments 
Manufacturer 
Model 
Serial number 
Due To Calibration 
Test Receiver   
Rohde&Schwarz 
ESCS30 833364/020 
2004. 
09 
Amplifier HP 
8447F 
2805A03351 2005. 
04 
Logbicon Super Ant. 
Schwarzbeck 
VULB9166 
1067 
2005. 04 
Position Controller 
EM Engineering N/A 
N/A 
N/A 
Turntable EM 
Engineering 
N/A 
N/A 
N/A 
 
8.2 Measurement Uncertainty 
         
        Radiated disturbance electric field intensity:                                                      ±3.0dB 
 
8.3 Test Parameters 
 
Port: 
Enclosure 
 
 
Basic Standard: 
EN55013: 2001 
Test Engineer: 
J. Y. Yu 
IF Bandwidth: 
120kHz 
Measurement Time: 
0.2Sec 
Frequency Range: 
30MHz – 1GHz 
 
 
 