WOORI Technology Inc.                                                Page 18 of 83 
                               DPR1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMI 
 
 
8.4 Test Data (Receiving Mode
 
T. Freq.*
Frequency
Pol.**
Reading
A.F + C.L
Result
Limit
Margin
(MHz)
(MHz)
(H/V)
(dB)
 +Amp*** (dB)
(dBuV/m)
(dBuV/m)
(dB)
87.5
98.20
V
39.9
-18.6
21.3
60.0
38.7
196.40
H
34.3
-14.6
19.7
52.0
32.3
294.60
H
28.0
-12.4
15.6
56.0
40.4
392.80
V
36.7
-9.7
27.0
56.0
29.0
98.0
108.70
V
44.0
-18.3
25.7
60.0
34.3
217.40
H
31.2
-14.3
16.9
52.0
35.1
326.10
H
26.8
-11.6
15.2
56.0
40.8
108.0
118.70
V
37.9
-18.3
19.6
60.0
40.4
237.40
H
32.4
-13.8
18.6
52.0
33.4
356.10
H
40.4
-10.6
29.8
56.0
26.2
 
 
 
*)   T. Freq. = Tuned Frequency ,  
**)    Pol. H = Horizontal    V = Vertical   
***) A.F. + C. L + Amp. = Antenna Factor + Cable Loss + Amplifier 
 
 
Comment 
        If no frequencies are specified in the tables, no measurement for quasi-peak was necessary. 
 
        Result 
    Compliant 