Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such terminals used
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II equipment
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
at 25 A ................... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
No such terminals
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
Not permanent wiring
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
N/A
Clamping of conductor and insulation if not soldered
or held by screws
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
sectional area of conductors, for the rated current of
the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A