Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 13 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
(see appended table 14)
N/A
Resistors separately approved ............................... :
No
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition
……:
Approved Y1-cap. (CY501,
CY502, CY504, CY506) used
CY502, CY504, CY506) used
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition
……:
X2 capacitor: CX501, CX502
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................. :
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................ :
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................ :
metal ........................................................................ :
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
(see appended table)
P
Transformers and inductors separately approved . :
No
N/A
14.3.2
General
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
between hazardous live parts and accessible parts
(double or reinforced insulation) .............................. :
Double or reinforced insulation
between T501, T502 primary
and secondary winding
between T501, T502 primary
and secondary winding
P
Coil formers and partition walls > 0,4 mm
T501 Bobbin: min. 1.0mm
T502 Bobbin: min. 0.9mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A