Read Harman Kardon BDS 575 EMC - CB Certificate online
Page 16 of 40
Report Ref. No.: 211-2012016-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Limited. - Shenzhen Branch
TRF No. IEC60065K
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950-1, Annex B
N/A
14.10
Batteries
Non-rechargeable batteries
used in the remote controller
used in the remote controller
P
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
P
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11
Optocouplers
Approved optocouplers (U505,
U506, U508) used.
Dti.≥0.4mm.
U506, U508) used.
Dti.≥0.4mm.
P
a) Comply with 13.6 (jointed insulation) and N.2.1
N/A
b) Comply with IEC 60747-5-5:2007
N/A
Alternative to a) and b) optocoupler comply with 13.8
N/A
14.12
Surge suppression varistors
Approved surge suppression
varistor RV501 used
varistor RV501 used
P
Comply with IEC 61051-2
P
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
P
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
P
15
Terminals
—
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Mains plug and appliance inlet
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
data
P
No risk of insertion in mains socket-outlets
P
Click on the first or last page to see other BDS 575 service manuals if exist.