BDS 570 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon BDS 570 (serv.man3) EMC - CB Certificate online

R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588      page 14 of 336 
 
 
3.6. Operating Condition of EUT 
3.6.1. Setup the EUT and simulators as shown in Section 3.2. 
3.6.2. Turn on the power of all equipments. 
3.6.3. Let the EUT work in test modes (BD Play/USB Play/BD Live/iPod Play/HDMI         
In/COAXIAL IN/OPTICAL IN/Component IN+AUX IN/FM Mode) and test it. 
3.6.4. BD Play: The EUT play BD signal disc(Color Bar video + 1kHz sound) and display   
the video on monitor. 
USB Play: The EUT play Color Bar video + 1kHz sound file from USB device and 
display the video on monitor. 
BD Live: The EUT play movie from Internet Via LAN cable and display the video on 
monitor. 
iPod Play: The EUT play Color Bar video + 1kHz sound file from iPod device and 
display the video on monitor. 
Component In + AUX In: The EUT play Color Bar video + 1kHz sound file from 
DVD Player. 
Coaxial In: The EUT play 1kHz sound file from DVD Player. 
Optical In: The EUT play 1kHz sound file from DVD Player. 
HDMI In: The EUT play Color Bar video + 1kHz sound file from DVD Player and 
display the video on monitor. 
FM Mode: The EUT received the RF signal of 88/98/108MHz and play 1kHz sound 
from S.G.. 
3.7. Test Procedure 
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT 
Power connected to the power mains through a line impedance stabilization network 
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains 
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm 
coupling impedance for the tested equipments. Both sides of AC line are checked to find 
out the maximum conducted emission levels according to the EN55013 and EN55022 
regulations during conducted emission test. 
 
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz. 
 
The frequency range from 150kHz to 30MHz is checked. The test result are reported on 
Section 3.8.   
3.8. Power Line Conducted Emission Test Results 
PASS. (All emissions not reported below are too low against the prescribed limits.) 
 
The EUT with the following test modes were tested and selected (mode 1 ~10) to read Q.P 
values, all the test results are listed in next pages. 
 
EUT: BLU-RAY DISC SYSTEM              Model No. : BDS570 
 
Test Date: Jun.28, 2011      Temperature: 29.5℃              Humidity: 55% 
 
 
 
 
Page of 127