                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377      page 14 of 323 
 
 
3.  POWER LINE CONDUCTED EMISSION TEST 
3.1. Test Equipments 
Item  Equipment 
Manufacturer 
Model No.  Serial No. 
Last Cal. 
Cal. Interval
1.  Test Receiver Rohde & Schwarz
ESHS10 
838693/001  Oct.31, 11 
1 Year 
2. 
L.I.S.N.#1 
Rohde & Schwarz ESH2-Z5 
834066/011  Oct.31, 11 
1 Year 
3. 
L.I.S.N.#3 
Kyoritsu 
KNW-242C
8-1920-1 
May.08, 12 
1 Year 
4. Terminator  Hubersuhner 
50
Ω 
No. 1 
May.08, 12 
1 Year 
5. Terminator  Hubersuhner 
50
Ω 
No. 2 
May.08, 12 
1 Year 
6. 
RF Cable 
Fujikura 
3D-2W 
No.1 
May.08, 12 
1Year 
7.  Coaxial Switch
Anritsu 
MP59B 
M50564 
May.08, 12 
1 Year 
8. 
Pulse Limiter Rohde & Schwarz ESH3-Z2 
100341 
May.08, 12 
1 Year 
9. 
Oscilloscope
Tektronix 
TDS3052B
B026036 
May.20, 12 
1 Year 
3.2. Block Diagram of Test Setup 
 
3.3. Test Standard 
EN55022: 2010 (Class B) and EN 55013: 2001+A1: 2003+A2:2006 
3.4. Power Line Conducted Emission Limit 
Limits dB(
μV) 
 Frequency 
MHz 
Quasi-peak Level 
Average Level 
0.15  ~
0.50 
66 ~ 56* 
56 ~ 46* 
0.50 ~
5.00 
56 
46 
5.00 ~ 30.00 
60 
50 
Notes: 1. *Decreasing linearly with logarithm of frequency. 
 2. The lower limit shall apply at the transition frequencies. 