IEC 60065, 6th edition : 1998
 - 
- Page 11 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°
C   
No temperature measured during heating test and fault 
cond. tests requires this test (7.2) to be performed. 
Tested parts 
Temperature   
under normal 
operating con- 
ditions (°C) 
Temperature   
under fault 
conditions   
      (°C) 
Softening 
temperature 
      (°C) 
 
 
 
 
 
 
 
 
 
 
 
 
 
CONSTRUCTIONAL 
REQUIREMENTS WITH REGARD 
TO THE PROTECTION AGAINST 
ELECTRIC SHOCK   
 
8.1 
Conductive parts covered by lacquer, 
paper, untreated textile oxide films 
and beads etc. considered to be 
bare   
Considered 
8.2 
Shock hazard when changing 
voltage setting device, fuse-links or 
handling drawers etc.   
Operation “By hand” not possible 
8.3 
Insulation of hazardous live parts not 
provided by hygroscopic material   
No hygroscopic materials 
8.4 
Risk of electric shock from 
accessible parts, including when 
covers are removed by hand. 
No cover removable by hand. 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous 
live parts and earthed accessible 
parts   
 
 
Resistors bridging basic insulation 
complying with 14.1 a)   
 
 
Capacitors bridging basic insulation 
complying with 14.2.1 a)   
 
 
Basic insulation bridged by 
components complying with 14.3.4.3 
 
 
Protective earth contact 
 