AVR 7500 (serv.man9) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 8 of 43 - 
 
 
   
 
Order No. 
200211175
 
 
 
 
7.1
 
U =
 
254,4 
V 
4 Ohm 
8 Ohm 
16 Ohm 
 
 
 Ohm 
 
Left 
right 
left 
right 
left 
right 
left 
right 
Measured max. output voltage  in Vp 
 
 
F) 41,1 
C) 41,3 
S) 41,1 
F) 41,1 
C) - 
S) 41,1 
 
 
 
 
Measured max. output power  in W
 
 
 
 
F) 105,4 
C) 106,5 
S) 105,8 
F) 105,4 
C) - 
S) 105,8 
 
 
 
 
Measured max. mains power in W
 
 
 
1046 
 
 
 
 
Operation of protective devices   
No fuse links operate during normal operating condition 
7.1.1 
Temperature rise of accessible parts   
(see table next page) 
7.1.2 
Temperature rise of parts providing 
electrical insulation   
(see table next page) 
7.1.3 
Temperature rise of parts acting as a 
support or as a mechanical barrier   
(see table next page) 
7.1.4 
Temperature rise of windings   
(see table next page) 
7.1.5 
Parts not subject to a limit under 
7.1.1 to 7.1.4   
(see table next page) 