Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 43 -
Order No.
200211175
Standardized approval marks
1
SCOPE
According to the standard
ü
2
DEFINITIONS
According to the standard
ü
3
GENERAL REQUIREMENTS
According to the standard
ü
Safety class of the apparatus
Class II
ü
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to the standard
ü
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power from
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
ü
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
SEE ATTACHED PHOTOES.
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
location
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
P
Rated supply voltage and symbol
AC-symbol (
~
)
230V
P
Rated mains frequency
50Hz
P
Rated current or power consumption
820W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet
”AC OUTLETS,
230V~50Hz, 100W MAX, SWITCHED,
230V~50Hz, 100W MAX, UNSWITCHED.
”AC OUTLETS,
230V~50Hz, 100W MAX, SWITCHED,
230V~50Hz, 100W MAX, UNSWITCHED.
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
P