IEC 60065, 6th edition : 1998
-
- Page 6 of 38 -
Order
No.
11152
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet;
”AC OUTLETS (~230V/50Hz),
UNSWITCHED (100W MAX),
SWITCHED (50W MAX)”
”AC OUTLETS (~230V/50Hz),
UNSWITCHED (100W MAX),
SWITCHED (50W MAX)”
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied.
P
Hazardous live terminals,
instructions for wiring
instructions for wiring
No live terminal.
N
Instructions for replacing lithium
battery
battery
No lithium battery
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No explanation required (indication in the form of
illumination)
illumination)
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF from
the mains, info required
connected equipment
If not completely switched OFF from
the mains, info required
The apparatus is not for permanent connection
N
6 HAZARDOUS
RADIATION
No radiation
N
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
N
6.2.1
Opening of any cover by hand
N
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
N
Labelling
N
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
N
Warning label requirement
N