Read Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 38 -
Order
No.
11152
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
1,79
A, P
=
334
W,
Pout =
2 x 8,5
W
(F)
1 x 8,4
W
(C)
2 x 7,8
W
(S)
2
x
8,9
W
(S/M)
LSL =
7 channels x 8
Ω
Ω
Ω
Ω
Loudspeaker
system(s)
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Right and Left for SB/MULTI channels.
Marking of loudspeaker terminals
FRONT, CENTER, SURROUND, SB/MULTI,
SPEAKERS ( 8
Ω
).
U =
254,4
V
6 Ohm
8 Ohm
16 Ohm
left left
right right left
right
left
right
Measured max. output voltage in Vp
F)
32,9
C) 32,8
S) 31,6
S/M) 33,8
S) 31,6
S/M) 33,8
F) 32,9
C) -
S) 31,6
S/M) 33,8
C) -
S) 31,6
S/M) 33,8
Measured max. output power in W
F)
67,6
C) 67,4
S) 62,6
S/M) 71,4
S) 62,6
S/M) 71,4
F) 67,6
C) -
S) 62,6
S/M) 71,4
C) -
S) 62,6
S/M) 71,4
Measured max. mains power in W
774
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P