AVR 507 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 10 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
HEATING  
 
t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
27,5 °C 
27,5 °C
 
 
t2 =   
25,5 °C 
25,5 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
 R2/
 
t measured 
t allowed * 
Insulation 
class 
  Main transf. pr. winding (207V) 
1,821 
2,193 
55,5 
85 
Class E 
  Sub transf. pr. winding (207V) 
2892 
3233 
32,9 
85 
Class E 
 
 
 
 
 
 
  Main transf. pr. winding (254,4V) 
1,821 
2,271 
66,7 
85 
Class E 
  Sub transf. pr. winding (254,4V) 
2892 
3383 
46,5 
85 
Class E 
 
 
 
 
 
 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed * 
Main transformer core 
41,2 
51,1 
85 
Sub transformer core 
26,3 
35,4 
85 
Diode, D991 body 
42,7 
48,6 
Diode, D992 body 
35,5 
39,7 
D992 
heat-sink 
36,2 40,5 - 
PWB near D992 
34,3 
38,9 
85 
TR, Q803 body 
48,7 
60,4 
TR, Q804 body 
32,8 
42,4 
TR, Q854 body 
46,6 
60,1 
PWB near Q804 
43,3 
55,4 
85 
E. Capacitor, C909 body 
17,9 
22,2 
E. Capacitor, C929 body 
34,8 
43,3 
IC91 
heat-sink 
47,6 63,6 - 
Resistor, R810 body 
36,4 
44,6 
Main 
heat-sink 
34,4 47,0 - 
Fan body (on heat-sink) 
29,6 
37,7 
60 
Fan body (on back cover)   
21,6 
26,2 
60 
Power cord bushing 
16,9 
21,6 
60 