AVR 445 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 17

Read Harman Kardon AVR 445 (serv.man2) EMC - CB Certificate online

  
Page 
15
 of 
31
 - 
 
 
www.nemko.com
 
Report No. 
72390 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.4 
High voltage components 
No high-voltage components. 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Approved fuses and thermal 
links 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Adequate external clearance 
and creepage distance 
14.5.1.1 
a) Thermal cut-outs separately approved 
None 
 
 
b) Thermal cut-outs tested as part of the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
The thermal link in main and 
sub transformers are 
separately approved, see list 
of critical components. 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are approved according 
to IEC 60127, see list of 
critical cmponents 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :
Correct marking applied close 
to the fuses; 
- Primary fuses, 
  F101: T5A L 250V 
  F201: T2A L 250V 
- Secondary fuses, 
  F501, F502, F505, F506: 
 T2A 250V 
  F601, F602, F701, F702: 
 T3.15A 250V 
14.5.2.3 
Not possible to connect fuses in parallel ............... :
No fuse holder so designed 
that fuse-links can be 
connected in parallel 
TRF No:  IEC/EN 60065F 
Page of 46
Display