Read Harman Kardon AVR 360 (serv.man2) EMC - CB Certificate online
Ref. No.:
LR500120906Q
Copyright
○
c
2009, LTA
CO., LTD
Page 6 of 17
3.2 IMMUNITY
3.2.1 Electrostatic Discharge
Definition:
The test assesses the ability of the EUT to operate as intended in the event of an electrostatic discharge.
We were performed the test according to LTA procedure QP-014.
Test method
: EN 61000-4-2
Discharge Impedance
: 330
Ω ±10% / 150pF ±10%
Type of Discharge (air discharge)
:
± 2kV, ± 4kV, ± 8KV
Type of Discharge (contact discharge)
:
± 2kV, ± 4KV
Number of discharges at each point
: 10 of each polarity
Discharge Repetition on Rate
: 1 / sec
Test mode
: PLAY mode
Performance Criteria
: B (Refer to the appendix 1)
Result
:
Complies
Measurement Data:
- Uncertainty(ESD) = +/- 5% (with a 95% confidence level, k=2)
“It has been demonstrated that the ESD generator meets the specified requirements in the standard with at least 95%
confidence.”
- refer to the Next page
TEST EQUIPMENT USED: 12, 45