Read Harman Kardon AVR 360 (serv.man2) EMC - CB Certificate online
Ref. No.:
LR500120906Q
Copyright
○
c
2009, LTA
CO., LTD
Page 8 of 17
3.2.2 RF e.m. field keyed carrier
Definition:
The test assesses the ability of the EUT to operate as intended in the presence of a radio frequency electromagnetic
field disturbance.
We were performed the test according to LTA procedure QP-014.
Test method
: EN 61000-4-3
Frequency range
: 900㎒ ±5㎒
Test level
: 3 V/m (measured unmodulated)
Duty cycle
: 1/8
Rep. frequency
: 217Hz
Test mode
: PLAY mode
Performance Criteria
: A (Refer to the appendix 1)
Result
:
Complies
Measurement Data:
- Uncertainty = +/- 1.6dB (with a 95% confidence level, k=2.28)
“It has been demonstrated that the RS generator meets the specified requirements in the standard with at least 95%
confidence.”
Result
Port
Test mode
Horizontal
Vertical
Remark
Enclosure PLAY
mode Complies
Complies
No reaction recognized
TEST EQUIPMENT USED: 22, 30, 31, 32, 33, 34, 35
Click on the first or last page to see other AVR 360 (serv.man2) service manuals if exist.