AVR 360 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon AVR 360 (serv.man2) EMC - CB Certificate online

Ref. No.:
 
LR500120906Q
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 9 of 17 
 
 
  3.2.3 Fast Transients common mode 
     
Definition: 
    The test assesses the ability of the EUT to operate as intended in the event of fast transients presence on one of the 
input/output ports. 
We were performed the test according to LTA procedure QP-014. 
 
Test method 
:  EN 61000-4-4 
Cable length 
:  < 3 m 
Test level   
:    0,5 kV (Signal /control ports) 
1,0 kV (AC Power input port) 
Polarity : 
 
Negative/ 
positive 
Repetition frequency 
:    5  ㎑ 
Test mode 
:  PLAY mode 
Performance Criteria 
:    B (Refer to the appendix 1) 
Result 
:  
Complies
 
 
Measurement Data: 
- Uncertainty = +/- 10% (with a 95% confidence level, k=2) 
“It has been demonstrated that the EFT/Burst generator meets the specified requirements in the standard with at least 
95% confidence.” 
AC power Line 
Test level 
Result 
Remarks 
+ 1kV 
Complies 
No reaction recognized 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
Complies 
No reaction recognized 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
- 1kV 
+ 1kV 
Complies 
No reaction recognized 
L - N 
- 1kV 
Complies 
No reaction recognized 
+ 1kV 
L – PE 
- 1kV 
+ 1kV 
N-PE 
- 1kV 
+ 1kV 
L-N-PE 
- 1kV 
 
TEST EQUIPMENT USED:    13, 14, 15, 45 
Page of 17