Read Harman Kardon AVR 3550 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 39 of 40 -
Order No.
200219130
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D901
S-c
254,4
A - C
14 min
F902
0,03 A
Pr. relay RY94 off immediately.
Input current stabilised at 0,03A.
Sub-transformer pr. winding heated
up to 121K and thermal fuse opened
after 14 min.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,03A.
Sub-transformer pr. winding heated
up to 121K and thermal fuse opened
after 14 min.
Dielectric strength test OK.
No hazard.
C906
S-c
254,4
-
13 min
F902
0,03 A
Pr. relay RY94 off immediately.
Input current stabilised at 0,03A.
Sub-transformer pr. winding heated
up to 123K and thermal fuse opened
after 13 min.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,03A.
Sub-transformer pr. winding heated
up to 123K and thermal fuse opened
after 13 min.
Dielectric strength test OK.
No hazard.
IC94
S-c
254,4
Pin 1 - 2
2 hr
F902
1,64 A
Normal operating.
No component damaged.
No hazard.
No component damaged.
No hazard.
C907
S-c
254,4
-
1 hr
F902
0,02 A
Pr. relay RY94 off immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C911
S-c
254,4
-
12 min
F902
0,03 A
Pr. relay RY94 off immediately.
Input current stabilised at 0,03A.
D902 damaged.
Sub-transformer pr. winding heated
up to 125K and thermal fuse opened
after 12 min.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,03A.
D902 damaged.
Sub-transformer pr. winding heated
up to 125K and thermal fuse opened
after 12 min.
Dielectric strength test OK.
No hazard.
Top
cover
opening
cover
opening
Blocked
254,4
-
10 min.
F902
F903
F904
F903
F904
1,62 A
Components are heated up to;
- Main transf. winding
- Main transf. winding
: 55K
- Main transf. core
: 50K
- Sub transf. pr. winding : 42K
- Sub transf. core
- Sub transf. core
: 36K
- PWB near D909
: 68K
- C917 body
: 26K
- TR, Q657 body
: 50K
and protection circuit operated (pr.
relay, RY94 off) after 10 min.
Dielectric strength test OK.
No hazard.
relay, RY94 off) after 10 min.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection