AVR 3550 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 42

Read Harman Kardon AVR 3550 (serv.man13) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
Q621 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
1,58 A 
Front L channel output off 
immediately. 
Input current stabilised at 1,33 A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
B - C 
30 min 
F902 
F903 
F904 
1,62 A 
Normal operating. 
Input current stabilised at 1,60A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
1,61 A 
Normal operating. 
Input current stabilised at 1,60A. 
No component damaged. 
No hazard. 
Q611 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
2,70 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q661 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
Protection circuit operated (pr. 
relay, RY94 off) immediately. 
R656 opened. 
Q611, Q657 shorted. 
R646, R651, R656 damaged. 
Input current stabilised at 0,01A. 
No hazard. 
Q661 
S-c 
254,4 
B - C 
30 min 
F902 
F903 
F904 
1,85 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q626 
S-c 
254,4 
C - E 
30 min 
F902 
F903 
F904 
1,93 A 
Protection circuit operated (pr. 
relay, RY94 off) after 4 sec. 
Input current stabilised at 0,01 A. 
No component damaged. 
No hazard. 
Q626 
S-c 
254,4 
B - E 
30 min 
F902 
F903 
F904 
1,17 A 
Front L channel output off 
immediately. 
Input current stabilised at 1,33 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 50
Display