AVR 3550 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 39

Read Harman Kardon AVR 3550 (serv.man13) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 40 - 
 
 
   
 
Order No. 
200219130
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
  26 °C 
Rated voltage   
230V~ 50Hz   
Remarks   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
D909 
S-c 
254,4 
AC - + 
30 min 
F902 
F903 
F904 
F904 opened immediately. 
Input current stabilised at 1,55A. 
No hazard. 
D909 
S-c 
207 
AC - + 
30 min 
F902 
F903 
F904 
F904 opened immediately. 
Input current stabilised at 1,49A. 
No hazard. 
D909 
S-c 
254,4 
AC - - 
30 min 
F902 
F903 
F904 
F903 opened immediately. 
Input current stabilised at 1,51A. 
No hazard. 
D901 
S-c 
254,4 
A - C 
30 min 
F902 
 
1,78 A 
R903 opened. 
Input current stabilised at 1,61A. 
No hazard. 
D904 
S-c 
254,4 
A - C 
30 min 
F902 
 
1,80 A 
FL display off immediately. 
R903, R904 opened. 
Input current stabilised at 1,57A. 
No hazard. 
C923 
S-c 
254,4 
30 min 
F902 
 
1,86 A 
FL display off immediately. 
Signal output off. 
R903, R904 opened. 
Input current stabilised at 1,12A. 
No hazard. 
C911 
S-c 
254,4 
30 min 
F902 
 
1,62 A 
Normal operating. 
Input current stabilised at 1,62A. 
No component damaged. 
No hazard. 
Q901 
S-c 
254,4 
B - E 
30 min 
F902 
 
1,62 A 
Normal operating. 
Input current stabilised at 1,62A. 
No component damaged. 
No hazard. 
Q901 
S-c 
254,4 
C - E 
30 min 
F902 
 
1,62 A 
Normal operating. 
Input current stabilised at 1,61A. 
No component damaged. 
No hazard. 
C907 
S-c 
254,4 
30 min 
F902 
 
1,79 A 
FL display off immediately. 
Input current stabilised at 1,63A. 
R901 damaged. No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 50
Display