Read Harman Kardon AVR 350 (serv.man3) EMC - CB Certificate online
- Page 10 of 14 -
www.nemko.com
Report No. 90401
13.3 – 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage (V)
Clearance
13.3.2
Creepage dist
13.4
Comm.
1 2
Up
Urms
Req.
Measu.
Req.
Measu.
Reinforce
Primary *)
Secondary
375
265
4,0 mm
12,5 mm 5,6 mm >12,5 mm
1)
*) 2N force applied.
Note: U in Volt, Clearances/Creepage Distances in mm, Comm.=Comment
Comments: 1) Measured between primary trace of switch pcb and near secondary trace of front pcb.