FAULT CONDITIONS TESTS
P
Voltage(V) 0,9 or 1,1 times rated voltage……….
253V
—
Ambient temperature(℃)……………………………
23 - 26
°C
—
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
Top
cover
opening
cover
opening
Top Blocked
253
23 min.
45 sec.
45 sec.
F901 2,35
A Unit shut down after 23 min 45 sec.
Input current stabilised at 0,018A.
Dielectric strength test OK.
No hazard.
Dielectric strength test OK.
No hazard.
Top
cover
opening
cover
opening
Side Blocked
253 3 hr.
F901
2,35 A
Normal operated.
The components are heated up to :
-Main transf. pr. Winging : 87,9K
-Main transformer core : 55,9K
-Sub transf. pr. Winging : 61,1K
-Sub transformer core
The components are heated up to :
-Main transf. pr. Winging : 87,9K
-Main transformer core : 55,9K
-Sub transf. pr. Winging : 61,1K
-Sub transformer core
: 49,9K
-PWB near D992
: 72,3K
-PWB near D991
: 77,4K
-PWB near Q803
: 50,9K
and stabilised.
Dielectric strength test ok.
No hazard.
Dielectric strength test ok.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded