AVR 350 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon AVR 350 (serv.man3) EMC - CB Certificate online

 
 
- Page 4 of 14 - 
 
 
www.nemko.com
 
Report No.  90401 
 
  
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
5 MARKING 
 
 
Comprehensible and easily discernible 
On front and rear side of the  
enclosure 
 
Permanent durability against water and petroleum 
spirit 
Tested with water / sprit 
5.1 Identification, 
maker, model  .................................... : 
Maker: “Harman kardon” 
Model: “AVR350/230” 
see copy of marking plate. 
 
Class II symbol if applicable 
Class II symbol is applied in 
according to IEC 60417-5172. 
 
Rated supply voltage and symbol  ........................... : 
AC-symbol ( ~ ) and  230V 
 
Frequency if safety dependant 
50Hz 
 
Rated current or power consumption  ..................... : 
400W 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
No fuse links operate during  
normal operating conditions. 
See also appended table. 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier 
(see appended table) 
7.1.4 
Temperature rise of windings 
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No temperatures measured  
during heating test and fault  
condition tests require this 
test (7.2) to be performed. 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
> 100 M
Ω after surge test 
10.2 Humidity 
treatment 48 h or 120 h  ........................... : 
120 h (40
°C). No impairment 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
 
Page of 23
Display