11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
FAN 
(built-in 
main heat 
sink - side)
 
Locked  253 
3hr 
F907 
2,35 A 
Normal operated. 
The components are heated up to :
-Main transf. pr. Winging  : 104,6K
-Main transformer core 
: 80,8K 
-Sub transf. pr. Winging  : 70,4K 
-Sub transformer core 
: 65,0K 
-PWB near Q803 
: 96,9K 
-PWB near D991 
: 98,6K 
-PWB near D992 
: 77,7K 
and stabilised. 
Dielectric strength test ok. 
No hazard. 
FAN 
(built-in 
main heat 
sink – center) 
Locked 253 
2hr 
45min 
F907 
2,35 A 
Unit shut down after 4 min. 
Input current stabilised at 0,018A. 
Dielectric strength test OK. 
No hazard. 
Pmax 
operating
 
- Maximu
m non-
clipped o
utput sig
nal 
253 
14 min 
F901 
5,26 A 
Main transformer primary winding 
heated-up to 141K and thermal  
fuse opened after 14 min. 
Input current stabilised at 0,018A. 
Dielectric strength test O.K. 
No hazard. 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 