Read Harman Kardon AVR 345 EMC - CB Certificate online
- Page 2 of 7 -
www.nemko.com
Report No. 79765
11
FAULT CONDITIONS TESTS
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V
—
Ambient temperature (
o
C) ...................................... :
24 -27
°C
—
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
D112
A - C
S-c
253
45 min
F901
2,35 A
Normal operated.
Input current stabilised at 1,34A.
R114
Input current stabilised at 1,34A.
R114
opened.
No hazard.
C124 - S-c
253
20 min
F901
2,35 A
Normal operated.
Input current stabilised at 2,35A.
R114 and R115
Input current stabilised at 2,35A.
R114 and R115
opened.
No hazard.
D114
A - C
S-c
253
23 min
F901
2,35 A
Normal operated.
Input current stabilised at 2,35A.
R104
Input current stabilised at 2,35A.
R104
opened.
No hazard.
D117
A - C
S-c
253
1 hr
24 min
24 min
F901
2,35 A
Normal operated.
Input current stabilised at 2,35A.
R105
Input current stabilised at 2,35A.
R105
opened.
No hazard.
D118
A - C
S-c
253
1 hr
F901
2,64 A
Normal operated.
Input current stabilised at 2,31A.
R116
Input current stabilised at 2,31A.
R116
opened.
No hazard.
C128 - S-c
253
20 min
F901
2,72 A
Output signal off immediately.
Input current stabilised at 0,80A.
R116 and R117
Input current stabilised at 0,80A.
R116 and R117
opened.
No hazard.
C129 - S-c
253
50 min
F901
1,40 A
Output signal off immediately.
Input current stabilised at 0,79A.
R116 and R117
Input current stabilised at 0,79A.
R116 and R117
opened.
No hazard.
C122
-
S-c
253
20 min
F901
2,35 A
FL display off immediately.
Input current stabilised at 2,34A.
R101
Input current stabilised at 2,34A.
R101
opened.
No hazard.
C117
-
S-c
253
20 min
F901
2,35 A
Normal operated.
Input current stabilised at 2,35A.
No component damaged.
No hazard.
Input current stabilised at 2,35A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection