AVR 345 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 48

Read Harman Kardon AVR 345 EMC - CB Certificate online

 
 
- Page 4 of 7 - 
 
 
www.nemko.com
 
Report No.  79765 
 
 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Location  Fault 
Test V 
Test  
time 
Fuse 
No. 
Current 
through 
fuse 
Temperature/Results 
Q803 
E - C 
S-c 
253 
10 min 
F901 
3,1 A 
Unit shut down immediately. 
Input current stabilised at 0,018A. 
Q803, Q804, R810 and  
R817 damaged. 
No hazard. 
Q803 
B - C 
S-c 
253 
10 min 
F901 
Unit shut down immediately. 
Input current stabilised at 0,018A. 
Q852, Q804, R810 and  
R818 damaged. 
No hazard. 
Q804 
E - C 
S-c 
253 
10 min 
F901 
10,1 A 
Unit shut down immediately. 
Input current stabilised at 0,018A. 
Q803, Q852, R810 and  
R817 damaged. 
No hazard. 
C807 
S - c 
253 
30min 
F901 
2,40 A 
Surr. L ch. output voltage dropped 
to 4,2V ac immediately. 
Input current stabilised at 2,2A. 
R821 opened. 
No hazard. 
D901 
A - C 
S-c 
253 
6 min 
F901 
2,39 A 
Sub transformer primary winding 
heated up to 97K and thermal fuse
opened after 5 min 14 sec. 
Dielectric strength test O.K. 
No hazard. 
C906 
S-c 
253 
10 min 
F901 
0,08 A 
Unit shut down immediately. 
Sub transformer primary winding 
heated up to 101K and thermal fuse
 opened after 5 min 42 sec. 
Dielectric strength test O.K. 
No hazard. 
Speaker 
terminal  
Front 
R ch. 
S-c 253 10 
min 
F901 
Unit shut down immediately. 
Input current stabilised at 0,018A. 
No component damaged. 
No hazard. 
Top cover 
opening 
- Blocked 
253 
min 
29 sec 
F901 
2,35 A 
Unit shut down after 5 min 29 sec. 
Input current stabilised at 0,018A. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
Page of 51