AVR 235 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 19

Read Harman Kardon AVR 235 EMC - CB Certificate online

- Page 5 of 7 - 
 
 
 
 
                     
Order No. 34137 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
24 - 26 °C 
Rated voltage   
230V~ 50Hz 
Remarks  
Comp. 
No 
Fault Test 
Short 
current 
Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Fan  
(Main 
heat-sink 
installed)
 
Locked 
254,4 
6 hr 
F907 
1,79 A 
Normal operated. 
The components are heated up to: 
- Main transf. pr. winding  : 74K 
- Main transformer core  : 58K 
- Sub transf. pr. winding  : 58K 
- Sub transformer core 
: 48K 
- D991 body 
: 58K 
- PWB near D991 
: 62K 
- Q803 body 
: 58K 
- PWB near Q804 
: 56K 
- Main Heat-sink 
: 65K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Top cover 
opening 
Blocked 
254,4 
20 min. 
F907 
1,79 A 
The components are heated up to: 
- Main transf. pr. winding  : 69K 
- Main transformer core  : 57K 
- Sub transf. pr. winding  : 56K 
- Sub transformer core 
: 51K 
- D991 body 
: 70K 
- PWB near D991 
: 73K 
- Q803 body 
: 75K 
- PWB near Q804 
: 76K 
- Main Heat-sink 
: 77K 
and Unit shut down after 13 min. 
Input current stabilised at 0,013A. 
Dielectric strength test OK. 
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 21
Display