HEATING  
 
t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
24,5 °C 
24,5 °C
 
 
t2 =   
24,9 °C 
23,5 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
 R2/
 
t measured 
t allowed *) 
Insulation 
class 
  Main transf. pr. winding (207V) 
1,807 
2,288 
68,5 
85 
Class E 
  Sub transf. pr. winding (207V) 
2747 
3235 
45,6 
85 
Class E 
  Main transf. pr. winding (254,4V) 
1,807 
2,305 
72,4 
85 
Class E 
  Sub transf. pr. winding (254,4V) 
2747 
3347 
57,6 
85 
Class E 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Main transformer core 
53,6 
57,5 
85 
Sub transformer core 
37,4 
45,0 
85 
Diode, D991 body 
61,5 
63,9 
PWB near D991 
61,9 
63,0 
85 
TR, Q803 body 
50,5 
59,5 
TR, Q804 body 
32,5 
38,9 
PWB near Q804 
48,1 
56,0 
85 
E. Capacitor, C909 body 
33,4 
36,8 
E. Capacitor, C916 body 
25,9 
29,0 
Resistor, R810 body 
44,2 
50,3 
Main 
heat-sink 
49,2 59,3 - 
Fan body (on heat-sink) 
31,8 
38,3 
60 
Power cord bushing 
26,6 
28,6 
60 
Top enclosure above main transformer 
30,3 
35,0 
65 **) 
Top enclosure above main heat-sink 
27,8 
33,5 
65 **) 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
**) Directly covering part for heat-sink and transformer. The top cover is supplied with 
ventilation openings covering most of the top cover. This indicate emission of heat from 
internal parts and the opening area is therefore not likely to be touched during normal 
use. Based on this the temp. rise is accepted also for Singapore. 
 
 
 
 
 