Read Harman Kardon AVR 230 (serv.man12) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 37 -
Order
No.
14399
Standardized approval marks
1
SCOPE
According to the standard
9
2
DEFINITIONS
According to the standard
9
3
GENERAL REQUIREMENTS
According to the standard
9
Safety class of the apparatus
Class II
9
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to the standard
9
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power from
the mains and at 1/8 of max. audio output power.
Positioned in a test box according to users instruction.
the mains and at 1/8 of max. audio output power.
Positioned in a test box according to users instruction.
9
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
P
Rated supply voltage and symbol
AC-symbol (
~
) and 230V
P
Rated mains frequency
50Hz
P
Rated current or power consumption
350W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet;
”AC OUTLETS (~230V/50Hz),
UNSWITCHED (100W MAX), SWITCHED (50W MAX)”
”AC OUTLETS (~230V/50Hz),
UNSWITCHED (100W MAX), SWITCHED (50W MAX)”
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
Click on the first or last page to see other AVR 230 (serv.man12) service manuals if exist.