IEC 60065, 6th edition : 1998
 - 
- Page 9 of 37 - 
 
 
   
 Order 
No. 
14399 
 
 
HEATING  
 
∆t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
24,5 °C 
24,5 °C
 
 
t2 =   
23,3 °C 
22,1 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
Ω R2/Ω 
∆t measured 
∆t allowed * 
Insulation 
class 
  Main transf. pr. winding (207V) 
2,42 
2,93 
55,8 
85 
Class E 
  Sub transf. pr. winding (207V) 
2728 
3141 
40,4 
85 
Class E 
 
 
 
 
 
 
  Main transf. pr. winding (254,4V) 
2,42 
3,08 
73,0 
85 
Class E 
  Sub transf. pr. winding (254,4V) 
2728 
3279 
54,7 
85 
Class E 
 
 
 
 
 
 
Other measured parts 
∆t measured 
at 207V 
∆t measured 
at 254,4V 
∆t allowed * 
Main transformer core 
48,6 
59,1 
85 
Sub transformer core 
32,4 
43,3 
85 
D992 heat-sink 
58,8 
62,7 
D991 heat-sink 
61,8 
66,5 
PWB near D992 
56,6 
60,1 
85 
TR, Q803 body 
49,3 
62,2 
TR, Q804 body 
36,5 
48,7 
TR, Q657 body 
51,7 
66,6 
PWB near Q657 
43,4 
55,1 
85 
E. Capacitor, C909 body 
26,6 
30,4 
E. Capacitor, C929 body 
36,5 
45,5 
IC91 body 
47,5 
61,8 
Main heat-sink 
50,3 
63,6 
Top enclosure above main transformer 
23,2 
30,5 
65 **) 
Top enclosure above main heat-sink 
34,5 
42,5 
65 **) 
Power switch button 
1,1 
1,3 
50 
 
Page of 49