Read Harman Kardon AVR 230 (serv.man12) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 37 -
Order
No.
14399
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
1,62
A, P
=
310
W,
Pout =
2 x 7,0
W
(F)
1 x 6,9
W
(C)
2 x 7,0
W
(S)
1
x
6,9
W
(S/B)
LSL =
6 channels x 8
Ω
Loudspeaker
system(s)
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Only one for Surround Back channels.
Marking of loudspeaker terminals
FRONT, CENTER, SURROUND, SURR.BACK,
SPEAKERS ( 8
Ω ).
U =
254,4
V
6 Ohm
8 Ohm
16 Ohm
left left
right right left
right
left
right
Measured max. output voltage in Vp
F)
30,0
C) 29,8
S) 29,9
S/B) 29,7
S) 29,9
S/B) 29,7
F) 30,0
C) -
S) 29,9
S/B) -
C) -
S) 29,9
S/B) -
Measured max. output power in W
F)
56,1
C) 55,4
S) 56,0
S/B) 55,3
S) 56,0
S/B) 55,3
F) 56,1
C) -
S) 56,0
S/B) -
C) -
S) 56,0
S/B) -
Measured max. mains power in W
734
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
Click on the first or last page to see other AVR 230 (serv.man12) service manuals if exist.