Report No.: 232105 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
35 
Water heater 
incorporated with 
residual current 
device(RCD) 
Testing to sub-clauses 9.9.2.1, 
9.9.2.2, 9.9.2.3 and 9.16 of SS 97: 
Part 1: 2000 are required. 
 N/A 
Applicable to multiway adaptor 
36 Multiway 
adaptor 
with 3-pin socket-
outlets or 
combination of 3-
pin and 2-pin 
socket-outlets 
a) The socket contacts of the 
adaptor shall only accept 13A 3-pin 
mains plug complying with SS 145 
and/or 2.5A 2-pin mains plug 
complying with EN 50075. 
b) The shutters screening the 
current-carrying socket contacts 
shall not be opened by the 
insertion of any corresponding 
SINGLE pin of the plug into any 
current-carrying socket aperture. 
c) A barrier or other acceptable 
means shall be provided on the 
engagement surface of the 2.5A 2-
pin socket-outlet of the adaptor to 
PREVENT entry of any types of 2-
pin mains plugs except those 
complying with EN 50075. (note: 
shutters cannot be regarded as 
barriers

d) Adaptor incorporates with switch 
would require additional test to 
sub-clauses 13.11, 17.1.3 and 
18.1.3 of SS 145: Part 2: 1997. 
No multiway adaptor 
N/A 
Applicable to plasma/LCD display monitor 
37 Plasma/LCD 
display monitor 
with TV tuner 
Plasma/LCD display monitor tested 
to IEC 60950 would require 
additional test to clauses 9 (related 
to antenna only), 10.1, 10.2, 10.3 
and 12.5 of IEC 60065. 
No Plasma/LCD display 
monitor 
N/A 
 
 
Page of 106