Read Harman Kardon AVR 161 (serv.man4) EMC - CB Certificate online
Page 2 of 6
Report No.: 232105
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
For apparatus intended to be used in not-tropical
climate regions, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R shall fixed to the equipment
at readily visible place.
"Only used in not-tropical climate regions."
climate regions, a warning label containing the
following or a similar appropriate wording or a
symbol as in annex R shall fixed to the equipment
at readily visible place.
"Only used in not-tropical climate regions."
If only symbol used, the explanation of the symbol
shall be contained in the instruction manual.
The statements above shall be given in a language
acceptable to the regions where the apparatus is
intended to be used.
shall be contained in the instruction manual.
The statements above shall be given in a language
acceptable to the regions where the apparatus is
intended to be used.
The apparatus intended to
be used in not tropical climate
regions, and a
be used in not tropical climate
regions, and a
ppropriate
wording provided as follows
See copy of marking plate.
P
5.1 e)
After the last paragraph, added:
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating
range, 220 V or three-phase 380V shall be covered.
For multiple rated voltages, one of them shall be
220 V or three-phase 380V and which default
setting from manufacture shall be 220 V or three-
phase 380V as well.
…….For single rated voltage, “220 V” or three-
phase “380V” shall be marked only. For a rating
range, 220 V or three-phase 380V shall be covered.
For multiple rated voltages, one of them shall be
220 V or three-phase 380V and which default
setting from manufacture shall be 220 V or three-
phase 380V as well.
Covered
P
5.1 f)
After the first sentence, Added:
……for Rated MAINS frequency or frequency range
shall be 50Hz or covered 50Hz.
……for Rated MAINS frequency or frequency range
shall be 50Hz or covered 50Hz.
Rated MAINS frequency of
50Hz covered.
50Hz covered.
P
5.4
Replaced the second sentence of the first
paragraph:
This information shall be given in normative
Chinese.
paragraph:
This information shall be given in normative
Chinese.
Adequate instruction supplied
by Chinese manual with the
apparatus.
by Chinese manual with the
apparatus.
P
5.4.1i)
Added new paragraph i),after the h) paragraph:
i) For apparatus incorporating antenna coaxial
sockets witch is non-separated with CATV network,
a warning wording or a similar shall be given in the
instructions manual:
“The CATV network connecting to this apparatus
shall separate from protective earth, otherwise it
may cause fire or other hazard.”
i) For apparatus incorporating antenna coaxial
sockets witch is non-separated with CATV network,
a warning wording or a similar shall be given in the
instructions manual:
“The CATV network connecting to this apparatus
shall separate from protective earth, otherwise it
may cause fire or other hazard.”
No CDS
N/A
Click on the first or last page to see other AVR 161 (serv.man4) service manuals if exist.