Read Harman Kardon AVR 161 (serv.man4) EMC - CB Certificate online
Page 4 of 6
Report No.: 232105
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.2
Replaced the fifth to seventh paragraphs by the
following:
The humidity treatment is carried out in a chamber
containing air with a relative humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃ and a
relative humidity of 93%±3% shall be subjected.
Apparatus intended to be used in non-tropical
climates are subjected to a relative humidity of
93%±3%.
The temperature in the chamber, at all places
where samples located, shall be maintained within
2℃of any convenient value between 20℃ and
30℃, as long as no condensation occur.
following:
The humidity treatment is carried out in a chamber
containing air with a relative humidity of 93%±3 %.
For apparatus, temperature of 40℃±2℃ and a
relative humidity of 93%±3% shall be subjected.
Apparatus intended to be used in non-tropical
climates are subjected to a relative humidity of
93%±3%.
The temperature in the chamber, at all places
where samples located, shall be maintained within
2℃of any convenient value between 20℃ and
30℃, as long as no condensation occur.
The apparatus intended to
be used in not tropical climate
regions, however p
be used in not tropical climate
regions, however p
erformed
for 120 h at temp. 40
C and
humidity 93 %.
N/A
Added Note 4: For apparatus intended to be
operated at altitudes between 2 000m and 5 000m,
the requirements for treatment of the insulating
material are under consideration.
operated at altitudes between 2 000m and 5 000m,
the requirements for treatment of the insulating
material are under consideration.
Noted.
11.1
Delete note 2.
Noted
11.1
After the ninth paragraph added a paragraph:
For apparatus intended to be used in tropical
climates, halve the values given above.
For apparatus intended to be used in tropical
climates, halve the values given above.
The apparatus intended to
be used in not tropical climate
regions
be used in not tropical climate
regions
N/A
12.5
Amended the first paragraph :
Antenna coaxial sockets to be mounted on the
apparatus shall subject to mechanical stress
caused in use, and the sockets incorporate with
parts or components which isolated HAZARDOUS
LIVE parts from ACCESSIBLE parts or protective
earth from other terminals.
Antenna coaxial sockets to be mounted on the
apparatus shall subject to mechanical stress
caused in use, and the sockets incorporate with
parts or components which isolated HAZARDOUS
LIVE parts from ACCESSIBLE parts or protective
earth from other terminals.
No such antenna
N/A
13.3.2
After the first paragraph, added a paragraph:
The requirements apply to apparatus intended to be
used at altitude not exceeding 2 000 m . For
apparatus intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with relevant multiplication factor in table
A.2 of GB/T 16935.1.
The requirements apply to apparatus intended to be
used at altitude not exceeding 2 000 m . For
apparatus intended to be operated at altitudes
between 2 000m and 5 000m , Minimum
CLEARANCE limits shall multiply with multiplication
factor 1.48 in table A.2 of GB/T 16935.1. For
apparatus intended to be operated at altitude more
than 5 000m , Minimum CLEARANCES limit shall
multiply with relevant multiplication factor in table
A.2 of GB/T 16935.1.
The apparatus intended to
be operated at altitudes up to
2 000m.
be operated at altitudes up to
2 000m.
N/A