Report No.: 232105 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
  
TRF No. IEC60065K 
 
10.2 
Replaced the fifth to seventh paragraphs by the 
following: 
The humidity treatment is carried out in a chamber 
containing air with a relative humidity of 93%±3 %. 
For apparatus, temperature of 40℃±2℃ and a 
relative humidity of 93%±3% shall be subjected. 
Apparatus intended to be used in non-tropical 
climates are subjected to a relative humidity of 
93%±3%.  
The temperature in the chamber, at all places 
where samples located, shall be maintained within 
2℃of any convenient value between 20℃ and 
30℃, as long as no condensation occur. 
The apparatus intended to  
be used in not tropical climate 
regions, however p
erformed 
for 120 h at temp. 40 
C and 
humidity 93 %. 
N/A 
 
Added Note 4: For apparatus intended to be 
operated at altitudes between 2 000m and 5 000m, 
the requirements for treatment of the insulating 
material are under consideration. 
Noted. 
 
11.1 
Delete note 2. 
Noted 
 
11.1 
After the ninth paragraph added a paragraph: 
For apparatus intended to be used in tropical 
climates, halve the values given above. 
The apparatus intended to  
be used in not tropical climate 
regions
 
N/A 
12.5 
Amended the first paragraph : 
Antenna coaxial sockets to be mounted on the 
apparatus shall subject to mechanical stress 
caused in use, and the sockets incorporate with 
parts or components which isolated HAZARDOUS 
LIVE parts from ACCESSIBLE parts or protective 
earth from other terminals.  
No such antenna 
N/A 
13.3.2 
After the first paragraph, added a paragraph: 
The requirements apply to apparatus intended to be 
used at altitude not exceeding 2 000 m . For 
apparatus intended to be operated at altitudes 
between 2 000m and 5 000m , Minimum 
CLEARANCE limits shall multiply with multiplication 
factor 1.48 in table A.2 of GB/T 16935.1. For 
apparatus intended to be operated at altitude more 
than 5 000m , Minimum CLEARANCES limit shall 
multiply with relevant multiplication factor in table 
A.2 of GB/T 16935.1.     
The apparatus intended to  
be operated at altitudes up to  
2 000m.
 
N/A 