Reference No. : 54120707A                                                                                                                        Page 8
 
◀  Anam EMC Test Laboratory  ▶
 
 
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz   
TO 1,000MHz
 
 
6.1. Operating environment 
Temperature 
: 30℃ 
Relative humidity  : 50% 
 
    6.2. Test set-up and procedure 
 
The measurement was performed on an open area test site with a reference   
 
ground plane and at a distance of 3m. The height of the measuring antenna was 
 
varied between 1 to 4m and the table was rotated a full revolution in order to 
obtain maximum value of the electric field intensity. The measurement was 
made in both the vertical and horizontal polarization, and the maximum value is   
presented in the report. 
The measurement was performed with a quasi-peak detector. 
Disturbance radiation due to the fundamental and harmonic frequencies of the 
local oscillator and the other source were measured on a selected number of FM 
sound broadcast channels. About the Disturbance radiation value from the other 
source, the sixteen maximum values were recorded. 
The test was measured with the main unit and the remote control unit. 
 
6.3. Measurement uncertainty 
 
Radiated disturbance electric field intensity, 30    ~    300 ㎒:  ±2.0 ㏈ 
 
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
6.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Open area test site 
Measurement 
Receiver 
R & S 
ESVP 
861743/024 
R & S 
ESCI 
100348 
 
Signal Generator 
Anritsu MG3632A 
MT79870 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Bi-conical Ant. 
Schwarzbeck 
VHA9103 
9103 1135 
Log-periodic Ant. 
Schwarzbeck 
UHALP9108-A 
91098(0793) 
Ant. Master 
EMCO 
1051-12 
90121554 
Turn table 
EMCO 
1080-1.211 
90121504 
 