Read Harman Kardon AVR 147 (serv.man3) EMC - CB Certificate online
Reference No. : 54120707A Page 7
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
R & S
ESCI
100348
Measurement
Receiver
Receiver
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
Signal Generator
Network EMCO 3825/2 90101718
Signal Generator
Anritsu
MG3632A
MT79870
R. C. Oscillator
Kenwood
AG-203A
3090241
/
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: June 12, 2007
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner
0.162 65.6 43.1 43.4 55.6 16.4 16.8
3.058 56.0 27.4 24.1 46.0 25.2 23.9
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner
0.154 65.8 45.3 44.7 55.8 17.6 16.9
0.174 65.3 43.3 42.8 55.3 15.4 15.2
CD 0.162 65.6 48.4 46.2 55.6 19.5 17.8
Mode
4.554 60.0 24.3 23.8 50.0 24.1 23.5
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).