5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
R. C. Oscillator
Network EMCO 3825/2 90101718
R. C. Oscillator
Kenwood
AG-203A
3090241
/
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: November 30, 2006
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .178 65.2 35.5 39.0 55.2 12.8 14.2
24.576 60.0 20.8 15.4 50.0 20.8 14.0
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .178 65.2 35.5 31.9 55.2 12.3 10.6
24.576 60.0 18.6 21.9 50.0 18.3 21.8
CD .178 65.2 44.4 43.9 55.2 16.9 16.8
24.576 60.0 20.3 21.6 50.0 19.8 21.2
The equipment does comply with the requirements.