Read Harman Kardon AVR 145 (serv.man2) EMC - CB Certificate online
DEMC#DR50120612D
Copyright ○
c 2006, DIGITAL EMC CO., LTD.
Page 9 of 18
6.2 RF e.m. Field Keyed carrier
RESULT : PASS
6.2.1 Measurement Procedure
The immunity against RF e.m. Field Keyed carrier was made accordance with EN55020:2002+
A1:2003.
A1:2003.
The test set-up was made accordance with EN61000-4-3:2002 in semi-anechoic
chamber. The EUT has been placed in center of a wooden turntable. The height of this table
was 0.8m. The field strength was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna and the equipment
under testing was at least 3m. The front side of the EUT shall be positioned parallel to the
antenna line of sight. The measurement was made in both the vertical and horizontal
polarization.
was 0.8m. The field strength was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna and the equipment
under testing was at least 3m. The front side of the EUT shall be positioned parallel to the
antenna line of sight. The measurement was made in both the vertical and horizontal
polarization.
Radio-frequency electromagnetic field. Keyed carrier.
Severity level
: 2
Field strength
: 3V/m
Frequency range
: 900MHz
Duty cycle
: 1/8
Rep. frequency
: 217Hz
Performance criterion