AURA (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon AURA (serv.man3) EMC - CB Certificate online

Report No.:  EM201300550-9             Application No.:  ZJ00032797              Page 9 of    69 
 
 
CS 
Signal generator 
ROHDE & 
SCHWARZ 
SML03 103002 
2014-11-13 
Power meter 
BOOTON 
4232A 
10543 
2014-09-26 
Amplifier 
PRANA R&D 
AP32 DT214 
0611-768 
2014-01-11 
CDN 
EMC PARTNER
L-801 M2/M3
2265 
2014-03-01 
Injection Clamp 
PRANA R&D 
IP-DR250 
0603-0729 
2014-06-26 
VOLTAGE DIP & VOLTAGE INTERRUPTIONS 
Main Interference 
Simulator 
EMC PARTNER
TRA2000 
851 
2014-05-30 
 
3.5 MONITORING OF EUT FOR THE IMMUNITY TEST 
Visual: 
Monitored the Spectrum Analyzer for any unintentional responses and any external 
change by the eyes for RS. 
Audio: 
Hear the sound from EUT by ear for ESD, RS, EFT, SURGE, CS and DIP. 
Monitor the SINAD by the Audio Analyzer for the audio signal performance. 
The audio reproduction functionality has been tested in accordance with EN 55013/EN 55020. 
The test results may be found in test report EM201300534-4. 
 
Page of 69
Display