Report No.:  EM201300550-9             Application No.:  ZJ00032797              Page 11 of    69 
 
turntable position of the above highest emission level were recorded for the final test. 
Procedure of Final Test 
EUT and support equipment were set up on the turntable as per the configuration with 
highest emission level in the preliminary test. The Analyzer / Receiver scanned from 
30MHz to 300MHz. Emissions were scanned and measured rotating the EUT to 360 
degrees, varying cable placement and positioning the antenna 1 to 4 meters above the 
ground plane, in both the vertical and the horizontal polarization, to maximize the emission 
reading level. Record at least six highest emissions. Emission frequency, amplitude, antenna 
position, polarization and turntable position were recorded into a computer in which 
correction factors were used to calculate the emission level and compare reading to the 
applicable limit and only QP reading is presented. The test data of the worst-case 
condition(s) was recorded. 
4.1.3 TEST SETUP 
 
Figure 1. 30MHz to 1GHz radiated emissions test configuration
 
 
 
Figure 2. Above 1GHz radiated emissions test configuration 