KV-TG213M50 - Sony TV Service Manual (repair manual). Page 71

Read Sony KV-TG213M50 Service Manual online

– 78 –
KV-TG213M50
   RM-GA002
2-10.
Conn Assy, 7UL Wire (1-923-000-81), Lead assy, Earth & Rotational Coil conn dressing
2-11.
HV Cap Assy dressing
Rotation Coil
Wire from 
Rotation Coil
D
Y
90
A:  Conn
 
Ass
y, 7
P
B:  Lead
 
Ass
y
, Earth
C:  UL Wire (1-923-000-81)
D:  Rotational Coil Conn
A    B     C    D 
Purse Lock Ø5
Lead assy,
Jumper
Lead assy,
Earth
Rotation coil 
Connector 
7
P
1) Dress HV cap assy with HV Holder as shown
     Note: Make sure the specified position is being followed.
2) Dress HV holder at DGC with purse lock, Ø9 as shown
3) Using  Yellow line (CRT Carbon line) as a reference to dress purse lock, Ø9.
 
180 ± 5 mm
HV Cable Holder
Place purse lock  Ø9 after the exit of DGC Conn from DGC
DGC
Purse Lock Ø9
Black tape
DGC Conn outlet
Gate (2 positions) of 
HV holder
Dress HV Cable at inner ring
HV Cable Holder
Dress HV Cable holder at the
DGC with 2 purse lock Ø9
HV Cap Assy
Page of 73