Read Sony KV-TG213M50 Service Manual online
– 76 –
KV-TG213M50
RM-GA002
2-6.
Earth Coating Assy installation at CRT
2-7.
Lead Assy, Speaker & DGC Conn dressing
Earth Assy,
Coating
Make sure the round
side of spring tension
is installed to Earth
Assy, Coating
side of spring tension
is installed to Earth
Assy, Coating
Figure
Hook the Right speaker
wire to CRT holder's
wire to CRT holder's
hook.
To avoid touch with
sharp edge and heatsink.
To avoid touch with
sharp edge and heatsink.
Right
speaker
speaker
Left speaker
Tight the Left Speaker assy,
Earth Lead Assy and
W034-W067,W035-W028
with Ø9 purse lock.
Earth Lead Assy and
W034-W067,W035-W028
with Ø9 purse lock.
A: Spk Wire (L)
B: Lead Assy Earth
B: Lead Assy Earth
C: Lead Assy Jumper
A
B
Purse Lock Ø9
Black tape
Ensure DGC Connector
is kept behind of DGC
is kept behind of DGC
Standing purse lock
DGC Connector in front of DGC before
dress with standing purse lock. Make
sure wire does not touch heatsink or
other high temperature parts.
dress with standing purse lock. Make
sure wire does not touch heatsink or
other high temperature parts.
Ensure DGC
Connector is kept
behind of black tape.
Connector is kept
behind of black tape.