Read Sony KV-SW21M30 Service Manual online
– 6 –
KV-SW21M30/M81/M83/M91/N60/P52
RM-GA002
1.7
A BOARD REMOVAL
1-8.
PICTURE TUBE REMOVAL
Note:
• The picture tube is upside down for (KV-SW21M30(Australia) only and the position for the anode cap and tension springs
are changed accordingly.
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
A Board
qd
Screw, Tapping 5 + Crown Washer (x4)
4
Anode Cap Removal
7
Degaussing Coil
6
Loosen the Neck Assembly
fixing screw and remove
Neck Assy & VM board
Neck Assy & VM board
qa
Loosen the Deflection Yoke
fixing screw and remove
fixing screw and remove
5
C Board Removal
9
Spring Tension
Removal (x2)
8
Holder, DGC
Removal (x2)
0
Earth Coating Assy
qs
Supports, CRT
Removal (x2)
Click on the first or last page to see other KV-SW21M30 service manuals if exist.