Read Sony KV-SR253M53 Service Manual online
– 12 –
KV-SR253M53
RM-GA002
2-10 i) Connector Assy wire dressing
2-10 ii) Connector Assy wire dressing
Dress Conn Assy, 7P RGB; Conn Assy, 5P
Dress DY connector; Conn Assy, 4P 200V;
Conn Assy 4P VM and Conn Ass, 6P using
purse lock
∅ 9 as shown.
Front In and Lead Assy, Earth using purse lock
∅ 9.
Keep wires away from heatsinks and high-temperature parts.
Note: Make sure DY connector is
inserted securely.-->prevent it from
coming out.
inserted securely.-->prevent it from
coming out.
Purse lock
∅ 9
Lead Assy, Earth
Conn Assy, 5P Front In
Purse lock
∅
9
Conn Assy, 7P RGB
CAUTION
Keep Conn Assy, 5P Front In wire in an
upward path from CN9201 to where it is
dressed with purse lock
∅ 9. This is to keep
it away from deflection area.
DY
Connector
Conn Assy
,
6P
Conn Assy
,
4P
200V
Purse lock
∅ 9
Conn Assy
,
4P
VM
Conn Assy, 6P
DY
Conn
Conn
Assy, 4P
Purse lock
∅ 9
Conn
Assy,
4P 200V
Keep Conn Assy, 5P Front In wire in an
upward path from CN9201 to where it is
dressed with purse lock
∅ 9. This is to keep
it away from deflection area.
Click on the first or last page to see other KV-SR253M53 service manuals if exist.