KV-LS212M90 - Sony TV Service Manual (repair manual). Page 14

Read Sony KV-LS212M90 Service Manual online

– 13 –
KV-LS212M90
   RM-GA002
2-17.  HV Lead Assy dressing
2-18.  AC Power Cord Dressing
Place purse lock Ø9 after the exit of DGC Conn from DGC
DGC
Purse Lock Ø9
Black tape
DGC Conn
outlet
180 ± 5 mm
HV Holder Combi
TVSR (Clause 9.4.7):
A)  Spacing between HV cable and conductive part's    
 
surface --> 1mm/kV or more
B)  Spacing between edge of anode cap and conductive 
 
parts --> 0.5mm/kV or more
C)  Spacing between HV cable & enclosure with   
 
ventilation (i.e. Rear Cover side) --> 10mm or more
45°
HV Holder Combi
Purse Lock Ø9
Fix the bigger diameter hook of HV 
Holder Combi on the right side of black 
tape & at horizontal bending of DGC, 
then use purse lock Ø9 to secure HV 
Holder Combi to DGC
B
A
A
A
A
C
SAFETY OPERATION
Dress HV Holder 
Combi with Purse Lock 
Ø9 as shown
HV Holder Combi
CAUTION:
Keep HV cable facing inwards DY to keep HV cable 
away from ventilation side of rear cover --> 10mm or more.
Ensure TVSR 1mm/kV is kept from HV cable to 
DY & other conductive parts
AC Cord Holder
AC Power Cord
Dress AC Power Cord with 
purse lock at rear cover
Purse Lock Ø8
Make sure AC Power Cord is
dressed between bottom cover 
boss and rail guide
Page of 69
Display