KV-DA34M50 - Sony TV Service Manual (repair manual). Page 3

Read Sony KV-DA34M50 Service Manual online

– 3 –
KV-DA34M50/M80/M86
RM-W105
Diagnostic
Item
Description
• Power does not
turn on
• +B overcurrent
(OCP)
• Horizontal
deflection failure
• +B overvoltage
(OVP)
• Vertical deflection
failure
• White balance
failure (no
PICTURE)
• 5V/9V Failure
• Micro reset
No. of times
STANDBY (1)
indicator flashes
Does not light
2 times
3 times
4 times
5 times
8 times
Self-diagnostic
display/Diagnostic
result
002:000 or
002:001~255
003:000 or
003:001~255
004:000 or
004:001~255
005:000 or
005:001~255
008:000 or
008:001~225
101:00 or
101:001~225
Probable
Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out F1601
(F1 Board)
• H.OUT Q6802 is shorted.
• C6831 is open circuit.
PS6606 open, PS6605
open.(D board)
• PH6602 faulty.
D6644 faulty, R6651 open.
• 10.5V is not supplied.
(D board)
• V.OUT IC6800 faulty
D6816 faulty
D6817 faulty
D6824 faulty
R6852 open
R6851 open (D board)
• G2 is improperly adjusted.
• CRT problem.
• Video OUT IC9001, 9002,
9003 are faulty. (C board)
• IC4301 (CXA2170Q)
(A board) is faulty.
• 5V Regulator (IC2601)
faulty.
• 9V Regulator (IC2600)
faulty.
• CRT Discharge (C Board)
• Static discharge
• External noise
Detected
Symptoms
• Power does not come on.
• No power is supplied to the
TV.
• AC power supply is faulty.
• Power does not come on.
• Load on power line is
shorted.
• H pulse output is too high.
• Power does not come on.
• Vertical deflection pulse is
stopped.
• Vertical size is too small.
• Vertical deflection stopped.
• No raster is generated.
• CRT cathode current
detection reference pulse
output is small.
• TV Blank
• No Raster
• Power is shut down shortly,
after this return back to
normal.
• Detect Micro latch up.
SELF DIAGNOSTIC FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER lamp will
automatically begin to flash.
The number of times the lamp flashes translates to a probable source of the problem. If an error symptom cannot be
reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past
problems and how often these problems occur.
1. DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY/TIMER lamp will flash a number of times to indicate the possible cause of the
problem. If there is more than one error, the lamp will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen. No error has occured if the screen displays a
“0”.
Page of 127