KV-32FV27 - Sony TV Service Manual (repair manual). Page 9

Read Sony KV-32FV27 Service Manual online

— 9 —
KV-32FV27 / 36FS13 / 36FS17 / 36FV27/ 38FS17
1.  Discharge the anode of the CRT and remove the anode cap.
2.  Unplug all interconnecting leads from the defl ection yoke, neck 
assembly, degaussing coils and CRT grounding strap.
3.  Remove the C and WA Board from the CRT.
4.  Remove the chassis assembly.
5.  Loosen the neck assembly fi xing screw and remove.
6.  Loosen the defl ection yoke fi xing screw and remove.
7.  Place the set with the CRT face down on a cushion and remove the 
degaussing coil holders.
8.  Remove the degaussing coils.
9.  Remove the CRT grounding strap and spring tension devices.
10. Unscrew the four CRT fi xing screws [located on each CRT corner] 
and remove the CRT  [Take care not to handle the CRT by the 
neck].
1-4. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, 
discharge CRT before attempting to remove the anode cap. Short between anode and CRT 
coated earth ground strap.
Coated
Earth
Ground 
Strap
ANODE CAP REMOVAL PROCEDURE
WARNING:  High voltage remains in the CRT even after the power is disconnected.  To avoid electric shock, discharge the CRT before attempting to 
remove the anode cap.  Short between anode and coated earth ground strap of CRT.  
NOTE:   After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT. 
REMOVAL PROCEDURES
HOW TO HANDLE AN ANODE CAP
1.  Do not use sharp objects which may cause damage to the surface of the anode 
cap. 
2.  To avoid damaging the anode cap, do not squeeze the rubber covering too hard. 
A material fi tting called a shatter-hook terminal is built into the rubber. 
3.  Do not force turn the foot of the rubber cover. This may cause the shatter-hook 
terminal to protrude and damage the rubber.
10
9
8
7
1
6
5
4
3
2
Turn up one side of the rubber cap 
inthe direction indicated by arrow  a  .
1
Use your thumb to pull the rubber
cap fi rmly in the direction indicated
by arrow  b  .
2
When one side of the rubber cap separates from 
the anode button, the anode cap can be removed 
by turning the rubber cap and pulling it in the 
direction of arrow  c  .
3
a
b
Anode Button
c