KV-32FV27 - Sony TV Service Manual (repair manual). Page 13

Read Sony KV-32FV27 Service Manual online

— 13 —
KV-32FV27 / 36FS13 / 36FS17 / 36FV27/ 38FS17
2-3.  FOCUS
1.  Input monoscope signal.
2.  Set user controls to normal.
3.  Set video mode to STANDARD.
4.  Set the PICTURE to maximum.
5.  Adjust at 325 Mark for best center/corner focus balance.
6.  Receive an entire white signal.  Make sure Magenta Ring is at an 
acceptable level.
Focus
Screen (G2)
35
325
35 MARK
325 MARK
CENTER
CIRCLE
2-4.  SCREEN (G2)
1.   Input dot pattern from the pattern generator.
2.   Set the user controls to NORMAL.
3.  Attach the G2-Jig to the C Board.
4.  Adjust RCUT, GCUT, BCUT, and SBRT in service mode with an 
oscilloscope so that voltages on the red, green, and blue cathodes 
are 170 ± 2.0 VDC.
 
5.  Observe the screen and adjust SCREEN (G2) VR  to obtain the faintly 
visible background of dot signal.
6.  Push the TEST + JUMP (+ Channel) to cut off the signal.  The screen 
should be bright or dark.  Brightness of raster must be increased 
when adjusting.
7.  Adjust screen VR until the screen is slightly cut off, or scarcely lights 
up.  A signal cannot be seen when the brightness of the raster is 
high.
8.  Push the JUMP again to release the cut off.
pedestal
GND
 170 ± 2.0 VDC
2-5.  WHITE BALANCE ADJUSTMENTS
NO.
24
25
26
27
28
29
36
Disp.
RDRV
GDRV
BDRV
RCUT
GCUT
BCUT
SBRT
Item
Red Drive
Green Drive
Blue Drive
Red Cut-off
Green Cut-off
Blue Cut-off
Sub Bright
All Models
*
31
31
14:Fix
7
7
7
1.  Set program palette to STANDARD and push RESET.
2.  Input an entire white signal.
3.  Set to Service Adjustment Mode.
4.  Set the PICTURE and BRIGHT to minimum.
5.  Adjust with SBRT if necessary.
6.  Set RCUT to “14”.
7.  Select GCUT and BCUT with  1  and  4  .
8.  Adjust with  3  and  6  for the best white balance.
9.  Set the PICTURE and BRIGHT to maximum.
10. Select GDRV and BDRV with  1  and  4  .
11. Adjust with  3  and  6  for the best white balance.
12. Write into the memory by pressing  MUTING  then  ENTER .
13. Repeat steps 1-12 for GDR4, BDR4, GCU4 and BCU4 using Video 4 
input. 
*Use values from Sub Contrast Adjustments
NOTE: White Balance should be adjusted after 
Sub Contrast because RDRV is also used in Sub 
Contrast Adjustment (See Page 22).
Page of 127
Display